Hacr rated breakers. Circuit breaker is suitable for HACR rated applications.
QBHW This circuit breaker is CSA-rated, HID-rated and HACR-rated, and UL Listed as High-Intensity Discharge. 5/80 Vdc, Extended Tang Line Terminal, Box Lug Load Terminal Terminal, Wire Size 8 To 1/0 AWG (Aluminum/Copper, Load), Bolt On Mounting, Approval UL 489, HACR approve for air HACR HACR is a term used to designate circuit breakers whic h have been certified to be used on multi-motor and combination loads such as are found in heating, air conditioning and refrigeration equipment. 7 and may used in this type of application. CAFCI and Dual Function Breakers and AFCI Receptacles While AFCI breakers can detect an arc that goes from Line to Neutral (parallel), CAFCI breakers are designed to detect a Line1-Line1 (series) arc such as inside an appliance’s damaged Please click document 0600DB0102 for a complete list of HACR labeled breakers. EG-Frame circuit breakers are HACR rated. Jan 6, 2024 · Time-delay fuses and HVACR-rated circuit breakers protect HVACR systems from motor start-up currents and prevent nuisance tripping, ensuring smooth and uninterrupted operation while promoting equipment longevity and reliability. Interrupting capacity 65 kiloampere at 240 VAC, 14 kiloampere at 480 VAC General Electric® Thick Breaker ^ 120/240 Vac ^ 15A ^ HACR/SWD Rated ^ Requires One 1" Space ^ Single Pole ^ Mfg #THQL-1115 looking for GHB2050 Featuring, 50A 2P, 277/480 Volt circuit breaker. UL Listed as SWD (switching duty) rated. New Plug-on Neutral NGH312033E - Eaton Series G electronic molded case circuit breaker, NG-frame, NG, Digitrip 310 RMS, Electronic LS trip, Three-pole, 1200 A, 480 Vac, 100 kAIC at 240 Vac, 65 kAIC at 480 Vac, Line and load, Imperial, 50/60 Hz, 80% rated New or Reconditioned Eaton GHB3060 Breakers. The EDB34050 is a 3-pole bolt-on circuit breaker, rated at 50A at a system voltage of 480Y/277V AC. Oct 23, 2003 · UL 489 (Standard on Molded Case Circuit Breakers) permits "HID" breakers to be rated up to 50A, whereas an "SWD" breaker is rated up to 20A. UL guide for LZLZ. 120 Vac Interrupting Rating. UL Listed Molded Case Circuit Breakers No. Nov 6, 2012 · GHB3030 Bolt-on 30 Amp,14k, HACR rated . The AmperaGeneral Electric RanGeneral Electric is 15 to 100 Eaton Cutler-Hammer GHB3020 Featuring 3 Pole, 277/480 Volt Bolt-on circuit breaker. Interrupt Sep 10, 2020 · HACR rated breakers open within a specified time curve, similar to a fuse, to protect group motor equipment (fans for combustion air, exhaust control, heated air handling, AC compressors, etc). Physical F-Frame circuit breaker 10–225 amperes Product description • All of Eaton’s F-Frame circuit breakers are HACR rated • All F-Frame thermal-magnetic circuit breakers 10–50A are suitable for HID (high intensity discharge) use • All F-Frame circuit breakers are suitable for reverse feed use Table 1. HD Supply Eaton Cutler-Hammer GHB3080 Featuring 3 Pole, 277/480 Volt Bolt-on circuit breaker. 5/80 Vdc, Extended Tang Line Terminal, Box Lug Load Terminal Terminal, Wire Size 8 To 1/0 AWG (Aluminum/Copper, Load), Bolt On Mounting, Approval UL 489, HACR approve for air Eaton® Cutler-Hammer® Circuit Breaker ^ 120/240 Vac ^ 30A ^ HACR Rated ^ Requires One 2" Space ^ Double Pole ^ Mfg #BR230. . UL Listed 5,000 AIR on 3Ø corner grounded delta systems. Circuit breaker type. When having a circuit breaker installed, check the latest National Electrical Code, section 210. No QBGF1020F - Eaton QB GFCI circuit breaker,Ground fault circuit breaker,Moisture-fungus treatment,20A,10 kAIC,Single-pole,120V,Non-Interchangeable,5 mA Trip sensitivity,QBGF Eaton CH thermal magnetic circuit breaker HACR rated, Two-Pole 120/240V Common Trip Requires Two 3/4-Inch Spaces Product Features. Jul 26, 2005 · All UL489 breakers are now HACR rated. single-, two- and three-pole, selected amperageavailable in switching duty, HACR, shunt trip and high magnetic setting Product specifications Interrupt rating Certifications UL Listed Circuit Breaker (File Number E197878) CSA Certified, VDE Certified, CE Marked HACR Rating (USA/Canada) Yes SWD Rating (USA/Canada) Yes (0. They are also switching duty rated for 120 VAC fluorescent light applications. 5/80 Vdc, Extended Tang Line Terminal, Box Lug Load Terminal Terminal, Wire Size 8 To 1/0 AWG (Aluminum/Copper, Load), Bolt On Mounting, Approval UL 489, HACR approve for air conditioning, heating and refrigeration Actuators and motion control; Backup power, UPS, surge & IT power distribution; Clutches and brakes; Conduit, cable & wire management; Cylinders; Differentials Aug 1, 2024 · Siemens Low Voltage Molded Case Circuit Breakers General Purpose MCCBs, TM - are Circuit Protection Molded Case Circuit Breakers. 3" 23/ 8" 31/ 8" 1-Pole 2-Pole 3-Pole 1P Breakers Handle Tie ECQTH2 1 ECQTH3 2 Handle Blocking Device ECQTH2 1 Aug 4, 2015 · An HACR circuit breaker is a heating, air-conditioning and refrigerator breaker. All EG-Frame thermal-magnetic circuit breakers 10 through 50 amperes are suitable for HID (high intensity discharge) use. Use only in 1Ø panel rated 150 A or greater. 00. Fixed. Square D QOB3100 Circuit Breaker (QOB) Standard, 100A, 3-Pole, 240 Vac, 3-Phase, Bolt-On, Black Jun 10, 2022 · The 3-Phase circuit breaker has three-spaces and mounting bolts to hold the breaker in place. This circuit breaker is CSA-rated, HID-rated and HACR-rated, and UL Listed as High-Intensity Discharge. Their current-carrying parts, mechanisms, and trip devices are contained in a molded case. AIR (25 kA). Proper circuit protection in HVACR applications is crucial for system safety and reliability. A standard two-pole HACR breaker can safeguard HVAC equipment from electrical overuse, according toBuild My Cabin. TABLE 1. Eaton® Cutler-Hammer® Circuit Breaker ^ 120/240 Vac ^ 60A ^ HACR Rated ^ Requires One 2" Space ^ Double Pole ^ Mfg #BR260. Marc Jul 16, 2000 · A HACR breaker is a type of circuit breaker that is listed for group applications. Circuit breakers with UL 489 listing are suitable for group motor applications requiring HACR designation. Long Time. UL does not require an HACR label on breakers, although they do offer one. Homeline circuit breakers are built with the same Square D brand quality you have come to expect at a price that makes them the best value in their class. 5-13 - Molded Case Circuit Breakers, Molded case switches and circuit breaker enclosures n EN 60947-1 AMD 2 - Molded case circuit breakers n EN 60947-2 AMD 2 2013 n EN 50581 2012 - RoHS compliant n All 3VA breakers are HACR rated per UL Applicable Standards: 3VA63 400A 3-Pole Description Catalog Number Siemens® Interchangeable Circuit Breaker ^ 120/240 Vac ^ 125 ^ HACR Rated ^ Requires 2" Space ^ Double Pole ^ Mfg #353255. Special features: UL listed for reverse feed applications, (AL) load side lugs installed. The SWD is common on single pole breaker { 15 and 20 amp size } for other sizes or multipoles it have to be ordered IIRC. Requires four spaces (1 AWG–300 kcmil Al/Cu). Currently they are manufactured by Eaton and are still the current series of Circuit Breakers for the PRL2A Panelboards. Search. Close ×. UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment haing motor group combinations and marked for use with HACR type circuit breakers. Pre-Owned · Square D If your using a welder, then bolt on breakers are a must. Be sure to use a HACR rated circuit breaker if so indicated on the nameplate (see Figure 3). No. Siemens offers one of most comprehensive lines of thermal magnetic circuit breakers. Interrupting capacity 65 kiloampere at 240 VAC, 14 kiloampere at 480 VAC These space saver duplex breakers combine two independent 1/2" breaker poles in a common unit. It is an ideal choice for NQ, /NQOD panel-boards. Suitable for Reverse Feed. Current Metering. HD Supply See full list on galvinpower. SQUARE D 3 Φ 240V 20 A HACR Circuit Breaker. 5/80 Vdc, Extended Tang Line Terminal, Box Lug Load Terminal Terminal, Wire Size 8 To 1/0 AWG (Aluminum/Copper, Load), Bolt On Mounting, Approval UL 489, HACR approve for air Eaton Quicklag Industrial Thermal-Magnetic Circuit Breaker, Three-pole, 50A, 22 kAIC, 240V, Bolt-on HACR rated. 489 ; Applications. Product Features. BAB3070H - Eaton BAB thermal magnetic circuit breaker,Quicklag industrial thermal-magnetic circuit breaker,70 A,10 kAIC,Three-pole,240 V,Interchangeable,BAB,Distribution panels 240V (Three-phase, four-wire maximum),Four-wire,Three-phase with 75° wire only for 50 amps and above, HACR rated. The tests for "HID" breakers include an endurance test at 75 percent power factor, whereas "SWD" breakers are endurance-tested at 100 percent power factor. GuideInfo Heating, Cooling and Ventilating Equipment in my reading states that you can use any type of c/b if the marking does not specify HACR. For use as a branch circuit breaker in 400 and 600 ampere panels only. Eaton Cutler-Hammer. 5/80 Vdc, Extended Tang Line Terminal, Box Lug Load Terminal Terminal, Wire Size 8 To 1/0 AWG (Aluminum/Copper, Load), Bolt On Mounting, Approval UL 489, HACR approve for air General Electric® Thick Breaker ^ 120/240 Vac ^ 20A ^ HACR Rated ^ Requires Two 1" Spaces ^ Double Pole Thick Breaker ^ Mfg #THQL-2120 Nov 16, 2006 · Class CTL panelboards or assemblies, in conjunction with Class CTL circuit breakers, prevent more circuit breaker poles from being installed than the number for which the equipment is rated. Frame Trip Ratings Frame Ampere Rating Jan 25, 2011 · However with the HACR rated breakers they should be stamped or printed somewhere in the breaker and the QO series it should be in front near the handle. Interrupting capacity 65 kiloampere at 240 VAC, 14 kiloampere at 480 VAC HACR HACR is a term used to designate circuit breakers which have been certified to be used on multi-motor and combination loads such as are found in heating, air conditioning and refrigeration equipment. GHB2070 Cutler Hammer Bolt-on Circuit Breaker, 14k rated HACR. Siemens® Interchangeable Circuit Breaker ^ 120/240 Vac ^ 20A ^ HACR Rated ^ Requires 2" Space ^ Double Pole ^ Mfg #352250. Learn where to buy QP Breakers, Duplex Breakers and QS Breakers here. HD Supply HACR rated (15–125 A, 1–, 2–, and 3–pole) UL ® Listed: file E84967, E84905, and E181374. The standard-rated CBs follow sizing rules outlined in the National Electrical Code (NEC). Interrupting capacity 65 kiloampere at 240 VAC, 14 kiloampere at 480 VAC If your using a welder, then bolt on breakers are a must. 5/80 Vdc, Extended Tang Line Terminal, Box Lug Load Terminal Terminal, Wire Size 8 To 1/0 AWG (Aluminum/Copper, Load), Bolt On Mounting, Approval UL 489, HACR approve for air BAB2030 Featuring Quicklag 2 Pole, 120/240 Volt AC, Quicklag bolt on HACR rated circuit breaker by Eaton Cutler Hammer or Westinghouse HACR Created with Sketch. Some manufacturers still print the phrase HACR for marketing purposes only, because some people want to see it in writing. All Circuit Breakers sold by JRL Electric Supply Inc. Choose from bolt-On Types BAB, QBHW, HBAX, HBAW. In other words, the breaker is able to supply proper protection for both the larger compressor motor circuit as well as the components of the smaller fan motor circuit. Schneider Electric/Square D Miniature circuit breaker with visi-trip indicator has an integrated pressure plate to offer protection against damage to flexible lines. Product Miniature circuit-breaker Range QO Current Rating 100 A Voltage Rating 120/240 V AC 240 V AC 120 V AC Mounting Type Plug-in Number of Poles 3P Circuit Breaker Type Standard Ratings HACR rated Electrical Connection Box lugs Complementary Interrupt Rating 10 kA 120/240 V AC 50/60 Hz 10 kA 240 V AC 50/60 Hz 10 kA 120 V AC 50/60 Hz If your using a welder, then bolt on breakers are a must. The circuit breaker has a thermal-magnetic trip unit and a signal indicator to indicate when a trip occurred. Interrupting capacity 65 kiloampere at 240 VAC, 14 kiloampere at 480 VAC NGS312033E - Eaton Series G electronic molded case circuit breaker, NG-frame, NG, Digitrip 310 RMS, Electronic LS trip, Three-pole, 1200 A, 480 Vac, 85 kAIC at 240 Vac, 50 kAIC at 480 Vac, Line and load, Imperial, 50/60 Hz, 80% rated Eaton® Cutler-Hammer® Circuit Breaker ^ 120/240 Vac ^ 40A ^ HACR Rated ^ Requires One 2" Space ^ Double Pole ^ Mfg #BR240. HACR rated. The EJB34050 is a 3-pole bolt-on circuit breaker, rated at 50A at a system voltage of 480Y/277V AC. Rated 240V (200A). 100%-rated CBs can handle continuous loads at full capacity, provided the assembly is listed and the conductors are correctly connected. HD Supply Mar 10, 2022 · All breakers listed to UL489 are HACR and have been for some 20 years or longer. This circuit breaker is CSA-rated, HID-rated and HACR-rated, and UL Listed as High-Intensity Discharge. QBHW Eaton Quicklag industrial thermal-magnetic circuit breaker, 30A, BAB type, 10 kAIC, Bolt-on mounting, Three-pole, Non-Interchangeable, 240V HACR rated. Type. 2 No. $14. Easy to securely install. Interrupting capacity 65 kiloampere at 240 VAC, 14 kiloampere at 480 VAC Nov 13, 2008 · Eaton's bolt-on miniature circuit breakers offer superior protection for panelboards. Breaker Catalog Numbers Switching duty rated for 120V AC fluorescent light applications. Built and listed to UL 489. In compliance with Federal Specification W-C-375B/GEN HACR Rating Bulletin 1489-M Circuit Breakers are rated as Heating, Air Conditioning and Refrigeration circuit breakers as defined by UL 489, paragraph 6. QBHW Square D Circuit Breaker QOB135 HACR RATED 1P 35 Amp Yellow Tab. Continuous Current Rated. Yes. SWD Rating The Bulletin 1489-M breakers (0. Toggle menu. Type: Type CH 3/4-Inch standard circuit breaker Wire Size: (1) #14-8 AWG, (2) #14-10 AWG Cu/Al Circuit Breaker Type: CH Used With: Type CH Loadcenters Voltage Rating: 120/240 V Amperage Rating: 30A 10-150A. 5/80 Vdc, Extended Tang Line Terminal, Box Lug Load Terminal Terminal, Wire Size 8 To 1/0 AWG (Aluminum/Copper, Load), Bolt On Mounting, Approval UL 489, HACR approve for air Aug 12, 2020 · AFCI breakers’ labeling must include the HACR rating, amperage rating and AIC (short circuit rating). are Brand New. Jun 20, 2024 · Eaton CH thermal magnetic circuit breaker HACR Rated. Standard. 800-380-4913 Login or Sign Up; 0. 35–60 A circuit breakers are suitable for use with 75°C conductors. All products 15-100A are HACR rated. Technical Data and Specifications Table 11-7 Eaton CH thermal magnetic circuit breaker HACR Rated. Years ago, breaker manufacturers were not consistent on this tripping time, hence HVAC equipment was typically certified by UL using fuses. 120/240 Vac Interrupting Rating. quoted below: Aug 23, 2012 · GHB Circuit Breakers were originally Manufactured by Westinghouse and then by Cutler Hammer. GSA Compliance. Sep 10, 2020 · HACR rated breakers open within a specified time curve, similar to a fuse, to protect group motor equipment (fans for combustion air, exhaust control, heated air handling, AC compressors, etc). HD Supply QBGF1015 - Eaton QB GFCI circuit breaker,Ground fault circuit breaker,Bolt-on mounting,15A,10 kAIC,Single-pole,120V,Non-Interchangeable,5 mA Trip sensitivity,QBGF Sep 28, 2021 · Section 7. TABLE 1-11. FRAME TRIP RATINGS 160 amperes is not a UL listed rating. 5/80 Vdc, Extended Tang Line Terminal, Box Lug Load Terminal Terminal, Wire Size 8 To 1/0 AWG (Aluminum/Copper, Load), Bolt On Mounting, Approval UL 489, HACR approve for air conditioning, heating and refrigeration Eaton Cutler-Hammer GHB3030 Featuring 3 Pole, 277/480 Volt Bolt-on circuit breaker. FRAME AMPERE RATING EGB 15 – 160 EGE If your using a welder, then bolt on breakers are a must. x . There is no longer a requirement for special testing. HD Supply QOB315 - Square D Bolt-On 15 Amp Breaker. This is usually important when the device is turned on and tends to draw more current than when it is in a running state. 5/80 Vdc, Extended Tang Line Terminal, Box Lug Load Terminal Terminal, Wire Size 8 To 1/0 AWG Aluminum/Copper, Load, Bolt On Mounting, Approval UL 489, HACR approve for air This circuit breaker is CSA-rated, HID-rated and HACR-rated, and UL Listed as High-Intensity Discharge. Eaton’s FAZ-NA DIN rail mountable circuit breaker is designed for use Quicklag Industrial Thermal-Magnetic Circuit Breaker, Single-pole, Non-Interchangeable, 40A, 22 kAIC, 120/240V HACR rated. TYPE BR BREAKERS, 1-INCH (25. The EJB34015 is a 3-pole bolt-on circuit breaker, rated at 15A at a system voltage of 480Y/277V AC. CSA ® Certified: file LR 40970. Eaton® Cutler-Hammer® Circuit Breaker ^ 120/240 Vac ^ 100 ^ HACR Rated ^ Requires One 2" Space ^ Double Pole ^ Mfg #BR2100. This unit plugs into one load center stab and requires one panel space. IEC only. They're used in enclosures, switchboards, panelboards, and load centers. org UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment haing motor group combinations and marked for use with HACR type circuit breakers. The EJB34040 is a 3-pole bolt-on circuit breaker, rated at 40A at a system voltage of 480Y/277V AC. It is ideally designed to offer superior overload and short circuit protection. All EG-Frame circuit breakers are suitable for reverse feed use. Sep 18, 2023 · The main function of a HACR-rated breaker is to provide protection against a momentary surge of electric current. 5/80 Vdc, Extended Tang Line Terminal, Box Lug Load Terminal Terminal, Wire Size 8 To 1/0 AWG (Aluminum/Copper, Load), Bolt On Mounting, Approval UL 489, HACR approve for air BAB1020D - Eaton Quicklag Industrial Thermal-Magnetic Circuit Breaker, 20A, BAB type, 10 kAIC, Bolt-on mounting, Single-pole, High Intensity Discharge, Non-Interchangeable, 120/240V Aug 10, 2018 · 11th edition of UL489, issued in 2009, accepted that any breaker UL listed under standard 489 also meets the requirements of the older HACR rating, effectively ending the concept of HACR ratings. May 8, 2013 · All breakers are now tested to HACR, and have been for quite a few years (maybe 10+). Brand New · Square D. 5/80 Vdc, Extended Tang Line Terminal, Box Lug Load Terminal Terminal, Wire Size 8 To 1/0 AWG (Aluminum/Copper, Load), Bolt On Mounting, Approval UL 489, HACR approve for air In Stock General Electric HACR Circuit Breaker, 15 Amp, 2-Pole, 30 Day Warranty. 10–30 A circuit breakers are suitable for use with 60°C or 75°C conductors. Product specifications. Choose Options. 12 (A) as requirements in most areas call for AFCI breakers in all rooms of the house The QB breakers are bolt-on versions of the Q Line used for bolting to the bus connections of load centers and lighting panels. Jul 7, 2004 · Re: HACR CIRCUIT BREAKER dana1028 I disagree about the HACR c/b's. HACR type –This marking indicates the circuit breaker is suitable for use with the group motor installations typically found in heating, air conditioning If your using a welder, then bolt on breakers are a must. QO circuit breakers meet the UL requirements for HACR circuit breakers and are suitable for group motor applications requiring HACR listing. 5 Of 1" Space ^ Single Pole Thin Breaker ^ Mfg #THQP-115 Aug 14, 2024 · Rated for use on single phase 120-Volt/240-Volt and 120-Volt/208-Volt VAC systems; 60°C/75°C conductor rated; HACR and SWD rated; Meets UL and CUL 489-requirements; Protection up to 10,000 Amp of available fault current; Return Policy Siemens® Interchangeable Circuit Breaker ^ 120/240 Vac ^ 100 ^ HACR Rated ^ Requires 2" Space ^ Double Pole ^ Mfg #Q2100. Physical ED-frame Siemens molded case circuit breakers are rated up to 125A and 480VAC and interrupt excessive current flows to protect devices from electrical damage. Choose from one, two or three-pole designs. Specifications may require breakers to carry the 'optional' UL label. n CSA-22. All Q Line circuit breakers feature Quick-make and Quick-break mechanisms, common trip bars, and easy to spot trip indication to ensure safety and reliability. So all breakers made (and listed) after 2009 no longer say "HACR", but they all meet it. Merci. Instantaneous. Section 7. Home renovation; New construction General Electric® Breaker ^ 120/240 Vac ^ 15A ^ HACR/SWD Rated ^ Requires . These space saver triplex breakers provide a 2 pole common trip breaker for 120/240V AC circuits and two single poles for 120V AC circuits. Suitable for switching 120 Vac fluorescent lighting loads. Quicklag Industrial Thermal-Magnetic Circuit Breaker, Two-pole, 100A, 22 kAIC, 120/240V , Bolt-on HACR rated. There are some UL proposals to eliminate the phrase HACR from different standards. Interrupting capacity 65 kiloampere at 240 VAC, 14 kiloampere at 480 VAC Eaton Quicklag Industrial Thermal-Magnetic Circuit Breaker, Two-pole, 15A, 22 kAIC, 120/240V , Bolt-on HACR rated. Two-Pole 120/240V Common Trip Requires Two 3/4-Inch Spaces. $402. Eaton QB GFCI circuit breaker, Single-pole, 5 mA Trip Sensitivity, 20A, 22 kAIC, 120V, Bolt-on mounting HACR rated. The ANSI-certified and UL-listed unit is rated for 120/240VAC and 10,000 AIR. Eaton CH Thermal magnetic circuit breaker, Type CHF 3/4-Inch standard circuit breaker, 15 A, 10 kAIC, Two-pole, 120/240V, CHF, Trip flag, common breaker trip, (1) #14-8 AWG, (2) #14-10 AWG Cu/Al, CHF, Type CH Loadcenters These circuit breakers are UL Listed and available as shown in the table. Interrupting capacity 65 kiloampere at 240 VAC, 14 kiloampere at 480 VAC XT1 and XT3 allow you to buy 480V when you need 480V, and save versus 600V rated breakers Thermal Magnetic trip units are offered up to 800A – offering savings versus electronic trip breakers Upgrade trip units in the field to support future plans, and use exactly the protections you need without buying ones you don’t with Ekip Touch trip units Switching duty rated. If your using a welder, then bolt on breakers are a must. Eaton Quicklag Industrial Thermal-Magnetic Circuit Breaker, 20A, BAB type, 10 kAIC, Bolt-on mounting, Three-pole, Non-Interchangeable, 240V HACR rated. Circuit breaker is suitable for HACR rated applications. The breaker provides overcurrent protection to combustion fans, exhaust controls, AC compressors and furnaces. 99. 2 Pole 120/240V Triplex . GFCI circuit Apr 10, 2024 · The circuit breaker is heating/air conditioning/refrigeration (HACR) rated—meaning it can handle sudden power surges—and typically for use with air conditioners, dryers, and water heaters. 277/480 Volt Panelboard PRL2 use for light industry. Circuit breaker accommodates 14 – 8 AWG copper and aluminum wires. HACR SWD. Physical Attributes. 5/80 Vdc, Extended Tang Line Terminal, Box Lug Load l Terminal, Wire Size 8 To 1/0 AWG (Aluminum/Copper, Load), Bolt On Mounting, Approval UL 489, HACR approve for air Shop Miniature Circuit Breaker, 20A, 240V, 3-Pole, 10kA, HACR Rated, Flush/Surface/DIN Rail By Square D (Schneider Electric) (QOU3205283) At Graybar, Your Trusted Resource For Miniature Circuit Breakers And Other Square D (Schneider Electric) Products. NOM ® 117 Certified. 10 KAIC. Protective Relays. Wire Range (Cu/Al) 14-8 kcmil / 12-8 kcmil. Various products available to support every conceivable application in power distribution systems. 4 MM) PER POLE 120/240, 10, 22 AND 42 kAIC — CLAMSHELLS Brand New or Used, Eaton/Cutler-Hammer GHB3040 3 Pole, 277/480 Volt Bolt-on circuit breaker. 120/240 Vac, 100 Ampere At 40 Deg C, Interrupting Rating 10000 Ampere At 120/240 Vac, 5000 Ampere At 24 To 48/62. Special Markings. Nov 3, 2012 · This breaker is compatible with Homeline load centers and CSED devices. Putting a specific HACR label on these breakers is optional and therefore only offered as a special by some manufacturers. Eaton BAB thermal magnetic circuit breaker,Quicklag industrial thermal-magnetic circuit breaker,125 A,10 kAIC,Two-pole,240 V,Non-interchangeable,BAB,120-240 V Shunt trip Contact me QB bolt-on dual function arc fault ground fault circuit interrupter brochure Eaton Cutler-Hammer GHB3050 Featuring 3 Pole, 277/480 Volt Bolt-on circuit breaker. 5 … 20 A) are rated as SWD (Switch Duty) and as such may be applied to switch HACR rated Switching duty rated for 120V AC fluorescent light applications Dimension Sheets — FRED Index 206 Product Selection Table 11-6. Homeline circuit breakers are the best in Regular circuit breakers don’t always trip in these instances because standard breakers are designed to respond to a sustained amount of heat, not a quick surge. Note: All Type BR 1-, 2- and 3-pole circuit breakers carry listing for HACR application. 3-Pole circuit breaker Type QRH2 HACR rated. For special low-magnetic breaker order BAB1015L1 or BAB1020L1. HD Supply If your using a welder, then bolt on breakers are a must. 8 of the 11th edition of UL 489 granted HACR listing to all UL 489 Listed circuit breakers. Visit the Eaton Store. Rated for use on Single-Phase 120/240 & 120/208 VAC systems ; 60⁰C/70⁰C conductor rated ; HACR and SWD rated ; Meets UL and cUL 489 requirements ; Protection up to 10,000 amps of available fault current ; Certification. 520 A) Calibration Temperature UL/CSA: 40 °C EN/IEC: 30 °C Rated Interrupting Capacity EN/IEC - Icu: 15 000 A UL/CSA (See Below) Trip Curve Rated Current (In) Interrupt Rating FAZ-NA circuit breakers PRODUCT OVERVIEW EATON UL 489 and UL 1077 DIN rail miniature circuit breakers Optimum and efficient protection Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant. Type: Type CH 3/4-Inch standard circuit breaker Wire Size: #14-2 AWG Cu/Al Circuit Breaker Type: CH Used With: Type CH Loadcenters Voltage Rating: 120/240 V Amperage Rating: 60A Trip Type: Common breaker trip Feb 5, 2024 · The circuit breaker used during our test has a standard rating of 80% or 100%. General information Ratings and markings Type Current range (A) HACR rated SWD marked HID marked 1 pole 15 - 125 15 - 125 15 - 20 15 - 50 2 pole 15 - 125 15 - 125 — 15 - 50 Oct 8, 2023 · looking for GHB2020 Featuring, 20A 2P, 277/480 Volt circuit breaker. Type: Type CH 3/4-Inch standard circuit breaker Wire Size: (1) #14-8 AWG, (2) #14-10 AWG Cu/Al Circuit Breaker Type: CH Used With: Type CH Loadcenters Voltage Rating: 120/240 V Amperage Rating: 20A looking for GHB2040 Featuring, 40A 2P, 277/480 Volt circuit breaker. May 20, 2024 · In general, regular circuit breakers are used to deliver and manage the current supply to various electronic devices, while a HACR breaker works similarly yet is considered the best option for HVAC equipment (like exhaust controls, combustion fans, furnaces, AC compressors, and refrigerators). 5/80 Vdc, Extended Tang Line Terminal, Box Lug Load Terminal Terminal, Wire Size 8 To 1/0 AWG (Aluminum/Copper, Load), Bolt On Mounting, Approval UL 489, HACR approve for air Eaton® Cutler-Hammer® Circuit Breaker ^ 120/240 Vac ^ 20A ^ HACR Rated ^ Requires One 1" Space ^ Single Pole ^ Type BR ^ Mfg #BR120. Toggle menu NGH312033E - Eaton Series G electronic molded case circuit breaker, NG-frame, NG, Digitrip 310 RMS, Electronic LS trip, Three-pole, 1200 A, 480 Vac, 100 kAIC at 240 Vac, 65 kAIC at 480 Vac, Line and load, Imperial, 50/60 Hz, 80% rated 3/4” CH Breakers • 1, 2, 3 pole breakers • 10kAIC @ 120/240V • HACR rated • Trip flag • Auto reset • Lifetime • warranty 1” BR Breakers • 1, 2, 3 pole breakers • 10, 22, or 42kAIC • HACR rated 10 year warranty Arc Fault Breakers • Standard LED indicates one of seven trip codes to simplify circuit diagnostics (Optional If your using a welder, then bolt on breakers are a must. cyew ebnws hsibu fuxebj kupo oiy kkavzd xzvz vcqb jcan